Backport of #233 to v3 (3.10.1). Fixes CxODEV-2161 and CxODEV-2000 (YouTrack) for the CxO engines, which pin ConductorSharp 3.10.x.

The three code commits from #233 cherry-picked cleanly: WorkflowEngineBackgroundService.cs and TaskQueuePollingService.cs were identical on master and v3. With them:

  • A ConductorSharp engine no longer stops polling for good after a Conductor error.
  • An HTTP timeout is no longer taken for a shutdown.
  • /health is Healthy only while the engine actually reads its queues.

See #233 for the root cause, design and before/after table.

Behaviour change to note: the old FTL Workflow Engine Background Service encountered an (API) error(s) is gone. Each failed attempt now logs at Error: ConductorSharp engine stopped polling (attempt N); retrying in …. Alerts that matched the old FTL text need updating.

Versions: Client, Engine, Patterns and KafkaCancellationNotifier go to 3.10.1. Toolkit stays 3.0.1-beta3.

Tests: v3 PRs get no CI, so this is the local run (LF checkout, net6.0 via DOTNET_ROLL_FORWARD=Major): 88/88 passed, including the 13 new unit tests and the 5 end-to-end recovery tests.

🤖 Generated with Claude Code

milansvitlica-codaxy and others added 4 commits October 19, 2026 13:44
…t is not a shutdown (CxODEV-2000)

WorkflowEngineBackgroundService ran the deployment and the execution manager
once. Any error, or an HTTP timeout mistaken for a shutdown, ended polling for
good while the host stayed up (and, for a timeout, stayed Healthy).

RunAsync is now a supervisor loop: deploy, mark running, run the execution
manager; on any error that is not our own shutdown, mark not running, log an
error, back off (1 s doubling to 30 s, 500 ms jitter) and start again. The
backoff resets after a successful deploy.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A real engine (DI wiring, hosted service, beta execution manager, HTTP
client) against a fake Conductor that answers 503, hangs (request timeout)
or loses the task-def registration race, then recovers. Each test checks
that the engine backs off, reports not running, and completes a task queued
after recovery; one also checks that a task in flight during the outage
still completes. All four fail on the old loop.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…shutdown cancel a hung deploy

Review findings on the supervisor loop:

- Health and the backoff reset followed a successful deploy, not a successful
  poll. With Conductor's metadata up and its task queues down (e.g. the queue
  backend), the engine reported Healthy most of the time while polling nothing,
  and redeployed about once a second on a 4xx. TaskQueuePollingService now marks
  the engine running after a successful read; the background service no longer
  marks it after deploy and restarts the backoff only after a run that polled.
  Unhealthy is still set only by the background service.
- Deploy takes no token, so a hung deploy blocked StopAsync. It now runs under
  WaitAsync(stoppingToken).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>